{"product_id":"altec-air-hre-series-130-scfm","title":"Altec AIR HRE Series Dual Tower Heat Regenerative Desiccant Air Dryer - 130 SCFM","description":"\u003ch2\u003e\u003cb\u003eHRE Series Heat Regenerative Desiccant Air Dryer\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003eThe \u003cspan class=\"s2\"\u003e\u003cb\u003eHRE Series\u003c\/b\u003e\u003c\/span\u003e from Altec AIR utilizes a low watt density heater to warm a regulated amount of dried process air, which then flows counter-current through the desiccant bed. This heated purge air removes moisture from the desiccant and is vented to the atmosphere—ensuring continuous, reliable drying performance.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eDesigned with \u003cspan class=\"s2\"\u003eASME\/CRN approved pressure vessels\u003c\/span\u003e and a \u003cspan class=\"s2\"\u003efeature-rich Pro-Logic Controller\u003c\/span\u003e, the HRE Series provides a rugged, dependable solution for industrial applications requiring high-quality air and reliable -40°F dew point performance.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eHeated purge system:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e uses low watt density heater and dry process air to regenerate desiccant\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eStandard outlet dew point:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e -40°F (-40°C), ISO 8573.1 Class 2\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eRegulated purge flow:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e optimized for efficiency regardless of operating pressure\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eFactory-installed filters:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e with differential pressure gauges and pre-filter timer drain\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eASME \/ CRN approved pressure vessels\u003c\/b\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eETL listed Pro-Logic controller:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e housed in a NEMA 4X enclosure\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003ePower requirements (model specific):\u003c\/b\u003e\u003cspan class=\"s1\"\u003e 120 VAC, 1 Phase, 60 Hz; 230 VAC, 1 Phase, 60 Hz; 460 VAC, 3 Phase, 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eMaximum pressure:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e 150 PSIG\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eMaximum operating temperature:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e 120°F (49°C)\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eTower pressure gauges \u0026amp; dew point indicators\u003c\/b\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eWelded frame base:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e forklift accessible for easy relocation\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eOSHA approved mufflers\u003c\/b\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eDesiccant fill \u0026amp; drain ports\u003c\/b\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eASME safety relief valves\u003c\/b\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp class=\"p1\"\u003e\u003cb\u003eOptional features:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e alternate voltages, EcoTronic dew point demand control, bypass packages (3-way, 6-way, 9-way), environment temperature kits, high pressure models (200 PSIG), upgraded controller, stainless steel control tubing and fittings, bolt-down construction\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Altec AIR","offers":[{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: none \\ Environment Temperature Protection: none","offer_id":45753631735962,"sku":"HRE-0130-1","price":22314.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: none \\ Environment Temperature Protection: none","offer_id":45753631768730,"sku":"HRE-0130-1-E","price":26096.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: 3-way \\ Environment Temperature Protection: none","offer_id":45753631801498,"sku":"HRE-0130-1-E3","price":26356.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: 6-way and dual selectable pre-filter \\ Environment Temperature Protection: none","offer_id":45753631834266,"sku":"HRE-0130-1-E6","price":27643.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: 9-way and dual selectable pre-filter and post-filter \\ Environment Temperature Protection: none","offer_id":45753631867034,"sku":"HRE-0130-1-E9","price":28552.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: 3-way \\ Environment Temperature Protection: none","offer_id":45753631899802,"sku":"HRE-0130-1-3","price":22574.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: 6-way and dual selectable pre-filter \\ Environment Temperature Protection: none","offer_id":45753631932570,"sku":"HRE-0130-1-6","price":23861.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: 9-way and dual selectable pre-filter and post-filter \\ Environment Temperature Protection: none","offer_id":45753631965338,"sku":"HRE-0130-1-9","price":24769.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: none \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753631998106,"sku":"HRE-0130-1-L","price":26166.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: none \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753632030874,"sku":"HRE-0130-1-EL","price":29948.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: 3-way \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753632063642,"sku":"HRE-0130-1-E3L","price":30208.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: 6-way and dual selectable pre-filter \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753632096410,"sku":"HRE-0130-1-E6L","price":31495.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: yes \\ Bypass and Dual Filter Kit: 9-way and dual selectable pre-filter and post-filter \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753632129178,"sku":"HRE-0130-1-E9L","price":32404.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: 3-way \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753632161946,"sku":"HRE-0130-1-3L","price":26426.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: 6-way and dual selectable pre-filter \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753632194714,"sku":"HRE-0130-1-6L","price":27713.0,"currency_code":"USD","in_stock":true},{"title":"Voltage: 120\/1\/60 \\ Dew Point Purge Control: none \\ Bypass and Dual Filter Kit: 9-way and dual selectable pre-filter and post-filter \\ Environment Temperature Protection: Add outdoor low ambient kit -20°F","offer_id":45753632227482,"sku":"HRE-0130-1-9L","price":28621.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0630\/0110\/0442\/files\/Altec-Air-HRE-Series-Desiccant-Dryer.jpg?v=1747653764","url":"https:\/\/penryair.com\/products\/altec-air-hre-series-130-scfm","provider":"Penry Air","version":"1.0","type":"link"}